Compare“Anchor Dead End clamp” has been added to the compare list
Compare“Brass Nut bolt” has been added to the compare list
“Anchor Dead End clamp” was added to the compare list
-
| Specification |
Details |
| Type |
Brass Bushing Rod / Transformer Rod Assembly |
| Application |
Used in oil-filled distribution and power transformers for electrical connection between winding and external terminals |
| Material |
High-conductivity Electrolytic Brass (CuZn39Pb3 or equivalent) |
| System Voltage |
Suitable for up to 33 kV |
| Mounting Type |
Through-bushing or terminal mounting |
| Operation |
Static electrical connection (non-moving part) |
| Connection Type |
Threaded both ends for nut tightening and secure connection |
| Standards Compliance |
IS 3347, IS 7421, IEC 60137 |
| Finish Type |
Natural polished brass / Tin-plated finish |
-
| Specification |
Details |
| Type |
MV (Medium Voltage) Tee Connector / Separable Connector |
| Application |
Used to connect medium voltage (MV) cables to switchgear, transformers, RMUs, or junction boxes |
| System Voltage |
11 kV / 22 kV / 33 kV (3 Phase, 50 Hz) |
| Connector Type |
Separable Tee Type (Plug-in) Connector |
| Insulation Type |
EPDM / Silicone Rubber (High-Grade Elastomer) |
| Conductor Compatibility |
Aluminium or Copper Conductors |
| Mounting Type |
Plug-in type connection to bushing or interface (as per EN 50180 / 50181) |
| Conductor Range |
25 mm² – 400 mm² |
| Operation |
Provides screened and fully insulated connection under load or energized conditions |
| Standards Compliance |
IEC 60502-4, IEEE 386, CENELEC HD 629.1.S2 |
| Design Interface |
Type C / Type A / Type B as per standard configuration |
| Installation Location |
Indoor / Outdoor (with screened protection) |
-
| Specification |
Details |
| Type |
Polymer (Polymeric Housed) Lightning Arrester |
| Application |
Used for protection of power distribution transformers, lines, and equipment from lightning and switching surges |
| System Voltage |
11 kV / 22 kV / 33 kV (3 Phase, 50 Hz) |
| Rated Voltage (Ur) |
12 kV for 11kV system; 24 kV for 22kV system; 36 kV for 33kV system |
| Nominal Discharge Current |
5 kA / 10 kA (8/20 µs waveform) |
| Mounting Type |
Pole or structure mounted (horizontal/vertical) |
| Housing Material |
Silicon rubber polymer housing (UV and weather resistant) |
| Design Type |
Gapless, metal oxide (ZnO) varistor type |
| Standard Compliance |
IEC 60099-4, IS: 3070 (Part 3) |
| Frequency |
50 Hz |
| Installation |
Outdoor installation for overhead or substation systems |
-
| Specification |
Details |
| Type |
Drop Out (DO) Fuse Wire / Fuse Element |
| Application |
Used in Drop Out (DO) fuse units for protecting 11 kV / 22 kV / 33 kV overhead power distribution lines and transformers |
| Material |
Tin-plated / Silver-plated Copper, Aluminum, or Special Fuse Alloy (e.g., Copper-Silver-Zinc) |
| System Voltage |
11 kV / 22 kV / 33 kV |
| Operation |
Melts under fault or overload current to isolate the faulty section |
| Mounting Type |
Fitted into DO fuse carrier / link assembly |
| Fuse Type |
Non-rewirable, high rupture capacity type |
| Standards Compliance |
IS: 9385 (Part I & II), IEC 282, and relevant Indian utility standards |
| Available Forms |
Wire form (spool), pre-cut lengths, or pre-fitted elements |
-
| Specification |
Details |
| Type |
Aluminium Compression / Crimping Type Lug |
| Application |
Used for terminating aluminium conductors in transformers, switchgear, control panels, and cable joints |
| Material |
High-conductivity aluminium (99.5% pure ETP grade) |
| Cable Compatibility |
Suitable for aluminium conductors from 10 mm² to 1000 mm² |
| Operation |
Crimped connection using standard hydraulic or mechanical tools |
| Mounting Type |
Bolt-on terminal connection |
| Temperature Range |
-20°C to +90°C (continuous) |
| Conductor Type |
Suitable for solid, stranded, or sector-shaped aluminium conductors |
| Standard Compliance |
IS 8309, BS 6121, DIN 46235, IEC 61238 |
| Finish Type |
Bright tinned or natural aluminium finish |
-
| Specification |
Details |
| Type |
Aerial Bunched Cable (ABC) |
| Application |
Used for overhead power distribution in low and medium voltage networks |
| System Voltage |
LV: 1.1 kV / MV: 11 kV or 33 kV (as per configuration) |
| Conductor Material |
Aluminium (Stranded, compacted, circular) |
| Insulation Material |
XLPE (Cross-Linked Polyethylene) / HDPE (High-Density Polyethylene) |
| Core Configuration |
2 Core / 3 Core / 4 Core + 1 Neutral (Messenger Wire optional) |
| Messenger Wire (Optional) |
Insulated or bare aluminium alloy wire for mechanical support |
| Frequency |
50 Hz |
| Conductor Standard |
IS: 8130 / IEC 60228 |
| Insulation Standard |
IS: 7098 (Part I & II), IEC 60502 |
| Installation Type |
Overhead (pole-mounted or wall-supported) |
-
| Specification |
Details |
| Type |
GI (Galvanized Iron) Hex Nut and Bolt Set |
| Application |
Used in transmission towers, pole line hardware, substation structures, and general-purpose fastening |
| Material |
Mild Steel / Carbon Steel (as per IS:1367) |
| Surface Coating |
Hot Dip Galvanized (HDG) |
| Thread Type |
Metric (MM) / UNC / UNF (custom options available) |
| Operation |
Manual fastening using wrench or spanner |
| Mounting Type |
Through-hole, clamping, or structure-mounted |
| Head Type |
Hexagonal head for easy torque application |
| Standard Compliance |
IS 1367, IS 3757, IS 1363, DIN 933/934 |
| Finish Type |
Hot dip galvanized zinc coating (minimum 40–80 microns) |
-
| Specification |
Details |
| Type |
Brass Hex Nut and Bolt Set |
| Application |
Used in electrical fittings, switchgear, transformers, busbars, and general-purpose fastening |
| Material |
High-grade brass (CuZn39Pb3 / IS 319 Type I) |
| Thread Type |
Metric (MM) / UNC / UNF (as per requirement) |
| Operation |
Manual fastening using wrench or spanner |
| Mounting Type |
Through-hole, clamp, or plate mounting |
| Head Type |
Hexagonal head for easy grip and torque application |
| Standard Compliance |
IS 1367, IS 319, BS 4183, DIN 933/934 |
| Finish Type |
Natural brass, nickel-plated, or chrome-plated (optional) |
-
| Specification |
Details |
| Type |
Copper Back Plate / Connector Plate |
| Application |
Used as a connecting terminal or mounting plate in transformers, switchgear, and electrical panels |
| Material |
High conductivity electrolytic copper (Cu-ETP / Cu 99.9%) |
| Mounting Type |
Bolt-on type for busbar, terminal, or bushing connections |
| System Voltage |
Suitable for up to 33 kV applications (depending on insulation and system design) |
| Operation |
Static mechanical and electrical connection component |
| Compatibility |
Fits transformer terminals, AB switch connectors, or heavy-duty earthing setups |
| Standards |
IS: 613, IS: 1897, IS: 1367, IEC 60439 |
| Design Type |
Flat plate with multiple precision-drilled holes for mechanical fastening |
-
| Specification |
Details |
| Type |
Outdoor, triple pole (3-phase), gang-operated Air Break (AB) Switch |
| Application |
Used for isolating or switching high-voltage power lines and equipment under off-load conditions |
| System Voltage |
11 kV, 22 kV, or 33 kV (3-phase, 50 Hz, solidly earthed neutral system) |
| Rated Voltage |
12 kV for 11kV system; 24 kV for 22kV system; 36 kV for 33kV system |
| Operation |
Manual operation through ground-level handle and GI pipe operating rod |
| Mounting |
Horizontal / Vertical mounting on pole or substation structure |
| Insulation Type |
Polymer / Porcelain post insulators (2 or 3 per phase) |
| Standard Compliance |
IEC 62271-103, IS: 9920 (Part I to IV), IS: 2544 |
| Design Type |
Tilting / Rotating gang-operated type with visible air gap |
-
| Specification |
Details |
| Type |
Suspension Clamp for LV ABC System |
| Application |
Used to suspend and support LV ABC (Aerial Bundled Cable) conductors on poles or walls at intermediate spans |
| System Voltage |
Up to 1.1 kV (Low Voltage Overhead Distribution Lines) |
| Cable Compatibility |
Suitable for 2-core, 3-core, or 4-core ABC cables (16 mm² – 95 mm²) |
| Installation |
Fixed on poles with a hook, bracket, or banding; tool-free mounting design |
| Operation |
Provides mechanical suspension without damaging the cable insulation |
| Mounting Orientation |
Vertical or horizontal pole mounting |
| Standards |
Conforms to NFC 33-040, EN 50483-3, IEC 61284, and relevant Indian Standards |
| Design Type |
Flexible swivel type allowing angular movement and vibration absorption |
-
| Specification |
Details |
| Type |
Insulation Piercing Connector (IPC) |
| Application |
Used for branching or tapping connections in LV Aerial Bundled Cable (ABC) systems without stripping insulation |
| System Voltage |
Up to 1.1 kV (Low Voltage Distribution Networks) |
| Cable Compatibility |
Main (Run): 16–95 mm², Tap: 16–95 mm² (as per image marking) |
| Operation |
Mechanical tightening with shear-head bolt ensuring perfect contact pressure |
| Installation |
Tool-operated, no stripping or pre-processing of cable insulation required |
| Mounting |
Suitable for overhead ABC systems and insulated copper/aluminum conductors |
| Standards |
Conforms to NFC 33-020, EN 50483-4, and IEC 61238 standards |
| Design Type |
Fully insulated, weatherproof, and UV-resistant clamp body |